TM 9-2350-311-20-1
3-3 TROUBLESHOOTING
CHART — CONTINUED
o. ENGINE WATER TEMP INDICATOR CIRCUIT —
(1) ENGINE WATER TEMP INDICATOR NEEDLE FAILS
CONTINUED
TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
CONTINUED FROM STEP B
I
1.
2.
I
Reconnect lead 33A to ENGINE WATER
3.
4.
5.
TEMP gage.
Disconnect lead 27 from ENGINE WATER
TEMP gage.
Place red lead of multimeter in lead 27
and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
I
I
I
2.
3.
4.
5.
Reconnect lead 27 to ENGINE WATER
TEMP gage.
Disconnect lead 27 from circuit breaker
output.
Place red lead of multimeter in circuit
breaker and black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
Go to step 1.
I
CONTINUED ON NEXT PAGE
TEMP gage (para 8-17).
1.
3-188