TM 9-2350-311-20-1
CONTINUED FROM STEP A
B
1. Reconnect lead 3526 to COOLANT indicator
light.
‘ 2. Disconnect portable instrument panel wiring
harness from portable instrument panel
disconnect.
3. Place jumper wires from pin A to socket A
(lead 27), and from socket P (lead 459B) to
socket C (lead 459).
4. Place a jumper wire from pin N (lead 352B)
to ground.
5. Turn MASTER switch ON and press
COOLANT indicator light.
6. Turn MASTER switch OFF.
Does COOLANT indicator light operate?
portable Instrument panel wrong
Repair or replace lead 352B of
harness (para 8-57).
1. Reconnect portable instrument panel wiring
harness to portable instrument panel
disconnect.
2. Disconnect battery ground leads.
3. Disconnect bulkhead-to-portable instrument
panel wiring harness from driver’s bulkhead.
4. Place jumper wires from pin B to socket B
(lead 400-459B), and from pin P (lead 352B)
to ground.
5. Reconnect battery ground leads.
6. Turn MASTER switch on and press
COOLANT indicator light.
7. Turn MASTER switch OFF.
Does COOLANT indicator light operate?
m
CONTINUED ON NEXT PAGE
3-197