TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 304 of 1275

TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART —
CONTINUED
p, TRANSMISSION OIL TEMPERATURE INDICATOR TRANSMISSION OIL TEMP INDICATOR NEEDLE FAILS
CIRCUIT — CONTINUED
TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
D
CONTINUED FROM STEP C
1. Reconnect lead 27 to TRANSMISSION OIL
2.
3.
4.
5.
6.
7.
8.
TEMP gage.
Disconnect battery ground leads.
Disconnect portable instrument panel wiring
harness from portable instrument panel
disconnect.
Place a jumper wire from socket P (lead
459B) to socket C (lead 459).
Place red lead of multimeters in socket A (lead
27) and black lead to ground.
Reconnect battery ground leads.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
Is voltage present?
Repair or replace lead 27 of portable
instrument panel wiring harness from
TRANSMISSION OIL TEMP gage (para
8-57).
CONTINUED ON NEXT PAGE
3-204


Back to Top