TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
p. TRANSMISSION OIL TEMPERATURE INDICATOR TRANSMISSION OIL TEMP INDICATOR NEEDLE FAILS
CIRCUIT — CONTINUED
TO MOVE OR IS UNSTEADY; ALL OTHER GAGES
OPERATE PROPERLY — CONTINUED
CONTINUED FROM STEP B
G
1. Reconnect lead 324 to TRANSMISSION OIL
TEMP gage.
2. Disconnect battery ground leads.
3. Disconnect portable instrument panel wiring
harness from portable instrument panel
disconnect.
4. Place jumper wires from pin A to socket A
(lead 27), from socket P (lead 459B) to
socket C (lead 459).
5. Reconnect battery ground leads.
6. Turn MASTER switch ON and check
TRANSMISSION OIL TEMP gage for
reading.
7. If TRANSMISSION OIL TEMP gage shows a
maximum reading, place a jumper wire from
pin L (lead 324) to ground.
8. Check gage for reading.
9. Turn MASTER switch OFF.
Does TRANSMISSION OIL TEMP gage show
minimum when grounded, and maximum when not
grounded?
1
Repair or replace lead 324 of portable
instrument panel wiring harness (para
8-57).
CONTINUED ON NEXT PAGE
3-206