TM 9-2350-311-20-1
CONTINUED FROM STEP D
I
E
1.
2.
3.
4.
5.
6.
Reconnect bulkhead-to-portable instrument
panel wiring harness to driver’s bulkhead.
Disconnect engine disconnect
bracket-to-
bulkhead wiring harness from engine
disconnect bracket.
Turn MASTER switch ON and check
ENGINE WATER TEMP gage for reading.
If gage shows a minimum reading, place a
jumper wire from socket K (lead 33A) to
ground.
Check gage for reading.
Turn MASTER switch OFF.
I
Does ENGINE WATER TEMP gage show minimum
when not grounded, and maximum when grounded?
Repair or replace lead 33A of engine
disconnect bracket-to-bulkhead wiring
I
harness (para 8-45, M109A2/M109A3;
8-46, M109A4/M109A5).
Repair or replace lead 33A of powerplant
wiring harness (para 8-43, M109A2/
M109A3; 8-44, M109A4/M109A5).
3-187