TM 9-2350-311 -20-1
CONTINUED FROM STEP E
F
.
3.
4.
5.
Reconnect lead 450 to circuit breaker output.
Disconnect lead 450 of driver’s instrument
panel wiring harness from connector near
circuit breaker.
Place red lead of multimeter in lead 450 and
black lead to ground.
Turn MASTER switch ON and check for
voltage.
Turn MASTER switch OFF.
is voltage present?
r
I
Repair or replace lead 450 of driver’s
instrument panel wiring harness (para
8-51).
Repair or replace lead 509E of
bulkhead-to-portable instrument panel
wiring harness (para 8-49).
END OF TASK