3-3 TROUBLESHOOTING CHART — CONTINUED
ae. ELECTRIC FUEL PUMP CIRCUIT — CONTINUED ENGINE MISSES WHEN LOW ON FUEL; ONE OR BOTH
FUEL PUMPS FAIL TO OPERATE — CONTINUED
CONTINUED FROM STEP C
D
1. Reconnect bulkhead-to-portable instrument
panel wiring harness to driver's bulkhead.
2. Disconnect battery ground leads.
3. Disconnect driver’s bulkhead-to-master relay
wiring harness from engine disconnect
bracket.
4. Place red lead of multimeter in socket B (lead
76B) and black lead to ground.
5. Reconnect battery ground leads.
6. Turn MASTER switch ON and check for
voltage.
7. Turn MASTER switch OFF.
I
Is voltage present?
I
Repair or replace lead 76B of driver's bulkhead-
to-master relay wiring harness (para 8-45,
M109A2/M109A3; 8-46, M109A4/M109A5).
1
I Repair or replace lead 76B of powerplant I
wiring harness (para 8-43, M109A2/
M109A3; 8-44, M109A4/M109A5).
3-328