TM 9-2350-311 -20-1
CONTINUED FROM STEP M
P
1. Reconnect bulkhead-to-driver’s instrument
panel wiring harness to driver’s bulkhead.
2. Disconnect lead 76B from engine oil pressure
switch.
3. Place red lead of multimeter in relay oil
pressure switch and black lead to ground.
4. Turn MASTER switch ON, start engine, and
run at 1000 rpm.
5. Check for continuity.
6. Turn MASTER switch and engine OFF.
Is continuity present?
I
I
Replace relay oil pressure switch
(para 8-9).
WARNING
I
Fuel is hazardous waste and must be disposed of in
accordance with local procedures or direction of local
I
Hazardous Waste Management office.
I
NOTE
Step Q must be performed before proceeding. Fuel line
arrangement will remain the same for steps R and S.
Q
1. Disconnect quick disconnect at primary fuel
2.
Remove male portion of quick disconnect
and elbow from fuel filter.
3. Install male portion of quick disconnect and
elbow on hose.
4. Connect assembled hose to fuel line and
place other end in five gallon container to
catch flowing fuel.
I
CONTINUED ON NEXT PAGE
3-337