TM9-2350-311-20-1
CONTINUED FROM STEP V
W
1.
2.
3.
4.
Reconnect lead 10 of circuit breaker-to-”Y”
connector lead to circuit breaker
input and disconnect from power lead
assembly.
Place red lead of multimeter in lead 10 and
black lead to ground.
Turn MASTER switch
voltage.
Turn MASTER switch
ON and check for
OFF.
Is voltage present?
I
I
Repair or replace lead 10 of power lead
assembly (para 8-54, M109A2; 8-55,
M109A2/M109A3; 8-56, M109A4/
M109A5).
Repair or replace circuit breaker-to-”Y’
END OF TASK