TM 9-2350-311 -20-1
CONTINUED FROM STEP A
B
1. Install LED in NBC indicator light assembly.
2. Disconnect lead 439L from NBC indicator
light assembly.
4. Place red lead of multimeter in lead 439L and
black lead to ground.
5. Turn MASTER switch ON and check for
voltage.
6. Turn MASTER switch OFF.
Is voltage present?
I
I
I Replace NBC indicator light
I
I
assembly (para 8-17).
I
Repair or replace lead 439L of ventilated face
piece system power harness (para 8-62).
END OF TASK