TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
ag. SLAVE START RECEPTACLE CIRCUIT (M109A2/NO POWER TO VEHICLE FROM SLAVE START
M109A3) — CONTINUED
RECEPTACLE; SLAVED VEHICLE HAD POWER WHEN
OPERATING — CONTINUED
CONTINUED FROM STEP B
I
c
1. Disconnect lead 50 from slave start
receptacle.
2. Place red lead of multimeter on lead 50 and
black lead to ground.
3. Check for continuity.
Is continuity present?
I
Replace slave start receptacle
ground lead (para 8-38).
[
D
1. Disconnect slave start cable from slave start
receptacle of vehicle being slaved.
2. Reconnect lead 50 to slave start receptacle.
3. Disconnect lead 81 from master relay.
4. Reconnect slave start cable to vehicle being
slaved.
5. Place red lead of multimeter on master relay
terminal and black lead to ground.
6. Turn MASTER switch to SLAVE and check
for voltage.
7. Turn MASTER switch OFF.
Is voltage present?
I
I
Repair or replace lead 81 of engine
disconnect bracket-to-bulkhead wiring
harness (para 8-45).
CONTINUED ON NEXT PAGE
3-354