TM 9-2350-311 -20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
ah. SLAVE START/EXTERNAL POWER
RECEPTACLE CIRCUIT (M109A4/M1O9A5)
The slave start receptacle is located in the driver’s compartment. The external power receptacle is located on the rear
hull bulkhead. When a slave start cable is connected between the slave start receptacles of two vehicles, one vehicle
can power the other vehicle’s electrical system. With the MASTER switch set to ON in the first vehicle and the MASTER
switch set to SLAVE in the second vehicle, 24 Vdc is supplied to the second vehicle’s master relay. This energizes the
master relay circuit which supplies voltage throughout the vehicle’s electrical system.