CONTINUED FROM STEP D
I
r
E
1. Reconnect lead 81 to master relay.
2. Disconnect power lead from driver’s
bulkhead.
3. Place red lead of multimeter in lead 49 and
black lead to ground.
4. Turn MASTER switch to SLAVE and
check for voltage.
5. Turn MASTER switch OFF.
Is voltage present?
lead assembly (para 8-55).
Repair or replace lead 49 of power
Troubleshoot master relay circuit (para
3-3b).
END OF TASK