TM 9-2350-311-20-1
(2) EXTERNAL POWER RECEPTACLE FAILS TO
OPERATE
.
Applicable Configurations
M109A4/M109A5
Tools
General mechanic’s tool kit (item 64, Appx H)
Multimeter (item 36, Appx H)
TA-1 probe kit (item 43, Appx H)
Equipment Conditions
Batteries disconnected (para 8-28)
A
1. Remove external power receptacle guard
(para 8-39).
2. Disconnect leads 496 and GND from
external power receptacle.
3. Using an external power source, apply 24Vdc
to the external power receptacle.
4. Place red lead of multimeter on external
power receptacle positive terminal (lead 496)
and black lead on negative terminal
(lead GND).
5. Check for voltage.
Is voltage present?
I
Replace external power receptacle
(para 8-39).
I
CONTINUED ON NEXT PAGE
3-361