TM-9-2350-311-20-1

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR HULL, POWERPLANT, DRIVE CONTROLS, TRACKS, SUSPENSION, AND ASSOCIATED COMPONENTS

AUGUST 1994

  TM-9-2350-311-20-1 - Page 462 of 1275

TM 9-2350-311-20-1
3-3 TROUBLESHOOTING CHART — CONTINUED
ah. SLAVE START/EXTERNAL POWER
(2) EXTERNAL POWER RECEPTACLE FAILS TO
RECEPTACLE CIRCUIT (M1 09A4/M109A5) —
OPERATE — CONTINUED
CONTINUED
CONTINUED FROM STEP A
B
1. Remove external power source from
external power receptacle.
2. Reconnect leads 49B and GND to external
power receptacle.
3. Disconnect NATO slave start-to-external
power wiring harness from driver’s bulkhead.
4. Reapply external power source.
5. Place red lead of multimeter on pin B (lead
49A) and black lead to ground.
6. Turn MASTER switch to SLAVE and check
for voltage.
7. Turn MASTER switch OFF.
Is voltage present?
I
Repair or replace lead 49A/49B of
NATO slave start-to-external power
wiring harness (para 8-63).
E
1. Reconnect NATO slave start-to-external
power wiring harness to driver’s bulkhead.
2. Disconnect lead 49 from batteries.
3. Place red lead of multimeter on lead 49 and
black lead to ground.
4. Turn MASTER switch to SLAVE and
check for voltage.
5. Turn MASTER switch OFF.
Is voltage present?
Repair or replace lead 49 of driver’s
bulkhead-to-batteries lead assembly
(para 8-86).
Troubleshoot battery circuit (para 3-3a).
END OF TASK
3-362