TM9-2350-311-20-1
b. Installatlon
Ensure engine and coolant system are cool enough to permit safe handling in
order to prevent bums.
Adhesives are toxic and flammable. Apply adhesives only in a well-ventilated area.
Avoid contact with skin, eyes, and clothes, and don’t breath vapors. Do not use
near heat, sparks, or open flame. Read and follow all warnings and instructions on
labels of adhesives. If contact with skin or eyes is made, wash area with water and
seek medical aid immediately.
Use adhesive at hose, tube, and casting interface when installing surge tank.
1 Install new gasket (21), relief valve (20), and four screws (19) onto block (22).
2 Install elbow (18) and hose (17) and screw on nut (16) at lower end of relief valve (20).
3 Place surge tank (15) back into position.
Hoses must cover unpainted areas of tubes and fittings or be positioned evenly
between red bands on tubes and housings.
4 Connect five hoses (10, 11, 12, 13, and 14) to surge tank (15).
7-11
WARNING
NOTE
NOTE