TM 9-2350-311 -20-1
8-12 TRANSMISSION OIL TEMPERATURE TRANSMlTTER AND TRANSMISSION OIL HIGH
TEMPERATURE SWITCH — CONTINUED
a. Removal — Continued
1 Disconnect electrical connector (1) of wire 324.
2 Unscrew and remove transmission oil temperature transmitter (2).
3 Disconnect electrical connector (3) of wire 509D.
4 Unscrew and remove high temperature switch (4).
b. Installation
1
2
3
4
WARNIN G
Ensure MASTER switch is OFF when working on electrical system to avoid electrical
shock and burns.
Install transmission oil high temperature switch (4).
Install electrical connector (3) of wire 509D.
Install transmission oil temperature transmitter (2).
Install electrical connector (1) of wire 324.
FOLLOW-ON
NOTE
MAINTENANCE:
Close right transmission access door (para 11-7)