NOTE
Proceed only as required.
a. Removal
Ensure MASTER switch is OFF when working on electrical system to avoid electrical
shock and burns.
1 Disconnect four electrical connectors (1).
2 Unscrew neutral safety switch (2) counterclockwise to remove from adapter (3). Remove pin (4) along with
switch.
b. Installation
Ensure MASTER switch is OFF when working on electrical system to avoid electrical
shock and burns.
1 Install pin (4) in adapter (3). Screw neutral safety switch (2) clockwise to install into adapter.
2 Install four electrical connectors (1).