TM 9–2350–311–20–2
3–48
Change 2
3–3
TROUBLESHOOTING CHART — CONTINUED
d.
ELEVATING SYSTEM — CONTINUED
(1)
CANNON DOES NOT ELEVATE OR DEPRESS
UNDER POWER OR MANUALLY, BUT HY-
DRAULIC PRESSURE IS NORMAL.
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
yes
no
A
Verify fault is corrected.
Continue normal opera-
tions.
Notify support mainte-
nance.
END OF TASK
1.
Check pressure of nitrogen charge in primary
accumulator assembly (para 19–5), secondary
accumulator (para 19–6), and manual pump
accumulator assembly (para 19–3).
2.
Charge as necessary (para 19–5, 19–6, and
19–3).
3.
Adjust equilibrated elevating system after
charging accumulators (para 6–3.1).
Does cannon elevate or depress?
EQUILIBRATED ELEVATING CYLINDER
SECONDARY ACCUMULATOR
PRIMARY
ACCUMULATOR