TM 9-2350-311-34-2
6-12 SAFETY RELIEF ELEVATION VALVE ASSEMBLY - CONTINUED
c. Assembly - Continued
3
Install two new preformed packings (8) in face of manifold assembly (5).
4
Install two new preformed packings (7) in face of bracket assembly (6).
NOTE
Position valve assembly so that plugs are at the bottom when attaching to manifold assembly and
bracket assembly.
5
Assemble bracket assembly (6), valve assembly (4), and manifold assembly (5).
6
Install four new lockwashers (2) and four cap screws (1) to secure components of safety relief elevation
valve assembly (3).
6-70