Procedural Steps:
WARNING
Corrosion Inhibitor contains alkali.
Do not get in eyes Wear
goggles/safety glasses when using.
Avoid contact with skin in
case of contact, immediately wash area with soap and water.
If
eyes are contacted, flush eyes with large amounts of water for
at least 15 minutes and get medical attention.
NEVER remove radiator cap on an engine until it has cooled,
however steam may be present.
Use a rag and remove radiator
cap slowly to prevent serious injury to personnel.
1.
Remove radiator cap and start engine.
2.
Add coolant to bring coolant to the proper level.
3.
Sprinkle or pour one of the materials listed above into the coolant.
4.
Inspect the hole for evidence of reduced or eliminated leakage.
5.
Add more material if leak has not stopped or has been reduced to an acceptable limit.
6.
Leave radiator cap loose.
7
Record the BDAR action taken.
When mission is complete, as soon as practical, repair the equipment/system
using standard maintenance procedures.
6-9