TM-9-2540-207-14-P

HEATER, VEHICULAR COMPARTMENT, MODEL: A20

TECHNICAL MANUAL; OPERATOR, FIELD, AND SUSTAINMENT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JULY 2007

  TM-9-2540-207-14-P - Page 174 of 288

TM 9-2540-207-14&P
6-10
4
CHECK WIRE HARNESS FOR
CONTINUITY AND SHORTS
CHECK 2 WIRES FROM THE VENT FAN BOARD TO THE
LOGIC BOARD FOR CONTINUITY:
P11-PIN12 TO P1-PIN3
P11-PIN4 TO P1-PIN12
CHECK
FOR MV SIGNAL
BETWEEN
P11-PIN13 AND P11-PIN5 FOR BT SENSOR
P11-PIN14 AND P11-PI N 6 FOR XT SENSOR
CHECK FOR A MINIMUM OF 150K RESISTANCE OR
OPEN LINE
BETWEEN
P11-PIN13 TO CHASIS GROUND AND
P11-PIN14 TO CHASIS GROUND
IF ANY CHECK FAILS
REPLACE WIRE HARNESS
RESTART HEATER
COMPLETE THE FOLLOWING CHECKS AT ROOM
TEMPERATURE AND WITH THE SENSOR HEATED TO
GREATER THAN 600C.
CHECK FOR MV SIGNAL BETWEEN
P11-PIN13 AND P11-PIN5 FOR BT SENSOR
P11-PIN14 AND P11-PIN6 FOR XT SENSOR
CHECK FOR GREATER THAN 10K
RESISTANCE BETWEEN;
P11-PIN13 TO CHASIS GROUND AND
P11-PIN14 TO CHASIS GROUND
IF ANY CHECK FAILS REPLACE WIRE HARNESS
RESTART HEATER
4
CHECK VENT FAN BOARD FOR LOOSE
SOLDER JOINTS
REPLACE VENT FAN BOARD
RESTART HEATER
5
CHECK LOGIC BOARD FOR LOOSE
SOLDER JOINTS
REPLACE LOGIC BOARD
RESTART HEATER
NOTE:
THIS FAULT MAY OCCUR ONLY WHEN THE SENSOR IS HEATED TO OPERATING TEMPERATURES.
AFTER COOLING THE FAULT CAN CLEAR ALLOWING THE UNIT TO BE STARTED, OPERATING BREIFLY
UNTIL THE SENSOR IS HEATED.