TM 9-2540-207-14&P
6-14
6.5.17 C9 - FUEL PUMP FAULT (Design Iteration 1 & 2 Only)
OPERATING PARAMETERS FOR THE FUEL PUMP ARE OUTSIDE NORMAL LIMITS
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK THAT ELECTRICAL CONNECTOR
IS ATTACHED TO FUEL PUMP
5.5.3
RECONNECT FUEL PUMP TO WIRING HARNESS
RESTART HEATER
2
DEFECTIVE FUEL PUMP
5.5.3
REPLACE FUEL PUMP
RESTART HEATER
3
DEFECTIVE ELECTRONIC PROGRAMMED
CONTROLLER BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED CONTROLLER
RESTART HEATER
4
DEFECTIVE WIRING HARNESS
5.5.6
REPLACE WIRING HARNESS
RESTART HEATER
NOTE:THE HEATER DOES NOT SHUT DOWN WHEN A C9 FAULT IS ENCOUNTERED, BUT WILL
CONTINUE TO OPERATE AT REDUCED PERFORMANCE.
6.5.18 C9 - FUEL PUMP FAULT (Design Iteration 3 Only)
OPERATING PARAMETERS FOR THE FUEL PUMP ARE OUTSIDE NORMAL LIMITS; FUEL PUMP OPEN
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK THAT ELECTRICAL CONNECTOR
IS ATTACHED TO FUEL PUMP AND
HARNESS TO POWER BOARD
5.5.3
RECONNECT FUEL PUMP TO WIRING HARNESS
RECONNECT PLUG P8 INTO POWER BOARD
RESTART HEATER
2
CHECK FUEL PUMP RESISTANCE
RESISTANCE SHOULD BE 7 TO 8 OHMS
IF RESISTANCE IS HIGH OR AN OPEN LINE
REPLACE FUEL PUMP
RESTART HEATER
3
CHECK
WIRING HARNESS FOR DAMAGE
AND CONTINUITY
CHECK 2 WIRES FROM
PLUG P7 TO POWER BOARD
PLUG P8:
P7-PIN A TO P8-PIN2
P7-PIN B TO P8-PIN1
IF ANY CHECK FAILS
REPLACE WIRING HARNESS
RESTART HEATER
4
DEFECTIVE POWER BOARD
REPLACE POWER BOARD
RESTART HEATER
5
DEFECTIVE LOGIC BOARD
REPLACE LOGIC BOARD
RESTART HEATER
NOTE: THE HEATER DOES NOT SHUT DOWN WHEN A C9 FAULT IS ENCOUNTERED, BUT WILL CONTINUE