TM-9-2540-207-14-P

HEATER, VEHICULAR COMPARTMENT, MODEL: A20

TECHNICAL MANUAL; OPERATOR, FIELD, AND SUSTAINMENT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JULY 2007

  TM-9-2540-207-14-P - Page 185 of 288

TM 9-2540-207-14&P
6-21
6.5.27 E4 - REVERSE BURNER AIR FLOW (Design Iteration 1 & 2 Only)
BURNER FAN IS MEASURING REVERSE AIR THROUGH THE HEATER, OR IS OPERATING OUT
OF RANGE
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK THAT DUCTING OF THE
COMBUSTION AIR SYSTEM TO THE
INLET AND THE EXHAUST DUCTING
ARE CORRECTLY ATTACHED TO
THE HEATER
2.2
RECONNECT COMBUSTION AIR DUCTING
CORRECTLY
RESTART HEATER
2
CHECK THAT COMBUSTION AIR AND
EXHAUST DUCTING IS FREE FROM
OBSTRUCTIONS
REMOVE OBSTRUCTIONS
RESTART HEATER
3
CHECK FOR CARBON
ACCUMULATION OR
OBSTRUCTIONS IN COMBUSTION
ASSEMBLY
5.3
REMOVE CARBON AND CLEAN COMBUSTION
ASSEMBLY
RESTART HEATER
CHECK CONDITION OF FLAME TUBE
AND BURNER CHAMBER
5.3.2
5.3.5
IF DISTORTED, REPLACE FLAME TUBE AND
BURNER CHAMBER
RESTART HEATER
4
DEFECTIVE BURNER FAN
5.5.4
REPLACE BURNER FAN PLATE
RESTART HEATER
5
DEFECTIVE HEAT EXCHANGER
5.4.1
REPLACE HEAT EXCHANGER
RESTART HEATER
6
DEFECTIVE ELECTRONIC
PROGRAMMED CONTROLLER
BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED
CONTROLLER
RESTART HEATER


Back to Top