DURING RUN OPERATIONS THE BURNER TEMPERATURE DROPS BELOW NORMAL OPERATING
LIMITS;- FLAME OUT DURNIG HIGH TO LOW
OR - XT BELOW FLAMEOUT THRESHOLD OR - BT
BELOW FLAMEOUT THRESHOLD OR - XT DROPPED MORE THAN 40C IN 8 SECONDS
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
12
CHECK WIRE HARNESS FOR
CONTINUITY AND SHORTS
CHECK 2 WIRES FROM THE VENT FAN BOARD
TO THE LOGIC BOARD FOR CONTINUITY AND
SHORT TO GROUND:
P11-PIN12 TO P1-PIN3
P11-PIN4 TO P1-PIN12
CHECK
FOR MV SIGNAL
BETWEEN
P11-PIN13 AND P11-PIN5 FOR BT SENSOR
P11-PIN14 AND P11-PI N 6 FOR XT SENSOR
CHECK FOR OPEN LINE BETWEEN
P11-PIN13 TO CHASIS GROUND AND
P11-PIN14 TO CHASIS GROUND
IF ANY CHECK FAILS
REPLACE WIRE HARNESS
RESTART HEATER
13
DEFECTIVE LOGIC BOARD
REPLACE LOGIC BOARD
RESTART HEATER
6.5.37 F3 - HEAT LIMIT (Design Iteration 1 & 2 Only)
VENT AIR OUTLET TEMPERATURE HAS EXCEEDED THE UPPER TEMPERATURE LIMITS OF
340°F (171°C) AND HEAT OUTPUT WILL BE REDUCED
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK THAT ALL DAMPERS IN
VEHICLE ARE OPEN
OPEN ALL DAMPERS FULLY
SWITCH HEATER TO LOW MODE
2
CHECK FOR OBSTRUCTIONS IN
FRONT OF HEATER VENTILATION
OUTLET
REMOVE OBSTRUCTIONS
SWITCH HEATER TO LOW MODE
3
CHECK ALL DUCTING
CONNECTIONS
VEHICLE TM
2.2
2.3
2.7
INSTALL DUCTING CORRECTLY
SWITCH HEATER TO LOW MODE
4
DEFECTIVE HEAT EXCHANGER
5.4.1
REPLACE HEAT EXCHANGER
RESTART HEATER