TM 9-2540-207-14&P
6-20
6.5.26 E3- LOW BURNER AIRFLOW (Design Iteration 3 Only)
HEATER DID NOT REACH MODE 04 WITHIN 3MINUTES 30 SECONDS; LOW BURNER
AIRFLOW – ON IGNITION TIME OUT OR
– LOW BURNER AIR FLOW IN STAGE 04 OR –
DURING RUN MODE
NOTE: IF ANY BURNER COMPONENTS ARE NEW, START-UP MAY REQUIRE 3 ATTEMPTS.
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK FOR OBSTRUCTIONS IN
COMBUSTION INLET OR EXHAUST
DUCTING
CHECK THAT EXHAUST IS SET-UP
TO MIL-PRF 62250D
REMOVE OBSTRUCTIONS
RESTART HEATER
2
CHECK FOR KINKING/BLOCKAGE
OF INLET DUCTING TO HEATER
REPLACE DEFECTIVE INLET DUCTING AND
REMOVE ALL UNNECESSARY BENDS
RESTART HEATER
3
IF AMBIENT TEMPERATURE IS
BELOW 32
°
F (0
°
C), CHECK FOR
FROST OBSTRUCTING HEATER
DUCTING
REMOVE FROST FROM AIR INLET
RESTART HEATER
4
AIR IN FUEL LINES.
PURGE HEATER AND BLEED FUEL LINES.
5
CHECK FOR CARBON
ACCUMULATION INSIDE BURNER
5.3.7
5.4.1
CLEAN BURNER HOUSING
CLEAN HEAT EXCHANGER
RESTART HEATER
CHECK CONDITION OF FLAME
TUBE AND BURNER CHAMBER
5.3.2
5.3.5
IF EITHER ONE IS DISTORTED, REPLACE FLAME
TUBE AND BURNER CHAMBER
RESTART HEATER
6
CHECK FOR WARPED BURNER
FAN PLATE; GAP BETWEEN
GASKET AND CASTING
5.5.4
REPLACE BURNER FAN PLATE
RESTART HEATER
7
DEFECTIVE BURNER FAN MOTOR
5.6.5
REPLACE BURNER FAN MOTOR
RESTART HEATER
8
DEFECTIVE BURNER FAN
IMPELLER
5.6.4
REPLACE BURNER FAN IMPELLER
RESTART HEATER
9
DEFECTIVE POWER BOARD
REPLACE POWER BOARD
RESTART HEATER
NOTE: OBSTRUCTIONS TO LOOK FOR IN COMBUSTION OR EXHAUST DUCTING INCLUDE: ICE, FROST,
DUST, MUD, WATER, FOREIGN OBJECTS, SOOT, RODENTS, SMALL BIRDS, ETC.