TM 9-2540-207-14&P
6-19
6.5.25 E3 - LOW BURNER AIR FLOW (Design Iteration 1 & 2 Only)
COMBUSTION AIR FLOW OPERATING LIMITS ARE OUT OF ALLOWABLE RANGE
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK FOR OBSTRUCTIONS IN
COMBUSTION INLET OR EXHAUST
DUCTING
REMOVE OBSTRUCTIONS
RESTART HEATER
2
CHECK FOR KINKING/BLOCKAGE
OF DUCTING TO HEATER
REPLACE DEFECTIVE DUCTING AND REMOVE
ALL UNNECESSARY BENDS
RESTART HEATER
3
IF AMBIENT TEMPERATURE IS
BELOW 32°F (0°C), CHECK FOR
FROST OBSTRUCTING HEATER
DUCTING
REMOVE FROST FROM AIR INLET
RESTART HEATER
4
CHECK FOR CARBON
ACCUMULATION INSIDE BURNER
5.3.7
5.4.1
CLEAN BURNER HOUSING
CLEAN HEAT EXCHANGER
RESTART HEATER
CHECK CONDITION OF FLAME
TUBE AND BURNER CHAMBER
5.3.2
5.3.5
IF EITHER ONE IS DISTORTED, REPLACE FLAME
TUBE AND BURNER CHAMBER
RESTART HEATER
5
DEFECTIVE BURNER FAN PLATE
5.5.4
REPLACE BURNER FAN PLATE
RESTART HEATER
6
DEFECTIVE ELECTRONIC
PROGRAMMED CONTROLLER
BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED
CONTROLLER
RESTART HEATER
7
AIR IN FUEL LINES.
PURGE HEATER AND BLEED FUEL LINES.
8
DEFECTIVE BURNER FAN MOTOR
5.6.5
REPLACE BURNER FAN MOTOR
RESTART HEATER
9
DEFECTIVE BURNER FAN DRIVER
BOARD
5.6.3
REPLACE BURNER FAN DRIVER BOARD
RESTART HEATER
10
DEFECTIVE BURNER FAN
IMPELLER
5.6.4
REPLACE BURNER FAN IMPELLER
RESTART HEATER
NOTE: OBSTRUCTIONS TO LOOK FOR IN COMBUSTION OR EXHAUST DUCTING INCLUDE: ICE, FROST,
DUST, MUD, WATER, FOREIGN OBJECTS, SOOT, RODENTS, SMALL BIRDS, ETC.