TM-9-2540-207-14-P

HEATER, VEHICULAR COMPARTMENT, MODEL: A20

TECHNICAL MANUAL; OPERATOR, FIELD, AND SUSTAINMENT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JULY 2007

  TM-9-2540-207-14-P - Page 187 of 288

TM 9-2540-207-14&P
6-23
6.5.30 E5 - INLET OVER PRESSURE (Design Iteration 3 Only)
AIR IS BEING FORCED THROUGH THE HEATER BY THE NBC SYSTEM AT STARTUP, OR
BURNER FAN OPERATING LIMITS ARE OUT OF RANGE
AIR PRESSURE IS GREATER ON THE INLET SIDE OF THE BURNER FAN THAN ON THE
EXHAUST SIDE
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
ENSURE ALL DUCTING TO HEATER
IS PROPERLY CONNECTED
2.3
2.7
RECONNECT DUCTING
RESTART HEATER
2
CHECK THAT NBC SYSTEM IS OFF
REF. APPROPRIATE VEHICLE TM
VEHICLE TM
TURN NBC SYSTEM OFF IF POSSIBLE
RESTART HEATER
RESTART NBC SYSTEM 5 MINUTES AFTER
HEATER ENTERS RUN MODE (07 OR 14)
NOTE:THIS IS A WARNING, THE AIR PRESSURE DIFFERENCE IS GREATER THAN 6 IWC; THE HEATER
WILL ATTEMPT TO OPERATE, BUT HAS THE POTENTIAL TO FLAME OUT.
6.5.31 E6 - HIGH VOLTAGE (Design Iteration 1 & 2 Only)
VOLTAGE SUPPLIED TO THE HEATER IS ABOVE NORMAL VOLTAGE LIMITS (19VDC - 30VDC
NORMAL RANGE)
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK THE SOURCE VOLTAGE OR
BATTERY LEVELS.
VEHICLE TM
IF VOLTAGE IS GREATER THAN 30VDC THEN
CHECK VEHICLE ALTERNATOR - SEE
APPROPRIATE VEHICLE TM
TURN HEATER OFF UNTIL VOLTAGE SYSTEM
REPAIRED
2
DEFECTIVE ELECTRONIC
PROGRAMMED CONTROLLER
BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED
CONTROLLER
RESTART HEATER