TM-9-2540-207-14-P

HEATER, VEHICULAR COMPARTMENT, MODEL: A20

TECHNICAL MANUAL; OPERATOR, FIELD, AND SUSTAINMENT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JULY 2007

  TM-9-2540-207-14-P - Page 192 of 288

TM 9-2540-207-14&P
6-28
6.5.35 F2 - BURNER FLAMEOUT (Design Iteration 1 & 2 Only)
DURING RUN OPERATIONS THE BURNER TEMPERATURE DROPS BELOW NORMAL
OPERATING LIMITS
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
CHECK IF VEHICLE FUEL FILTER
IS PLUGGED
VEHICLE TM
REPLACE FUEL FILTER
RESTART HEATER
2
CHECK FOR AIR BUBBLES IN THE
FUEL LINE.
BLEED AIR FROM FUEL LINES.
3
CHECK TO SEE IF FUEL LINE
LEADING TO HEATER IS PINCHED
OR OBSTRUCTED
STRAIGHTEN FUEL LINES AND REMOVE
OBSTRUCTIONS
RESTART HEATER
4
CHECK THAT THERE IS AMPLE
FUEL SUPPLY
TABLE 2-1
FILL FUEL TANK WITH FUEL
RESTART HEATER
5
CHECK FOR OBSTRUCTIONS IN
ALL HEATER DUCTING
REMOVE OBSTRUCTIONS
RESTART HEATER
6
CHECK FOR CARBON BUILD-UP
ON BURNER FUEL SHAFT
5.3.7
CLEAN FUEL SHAFT
7
CHECK FOR CARBON
ACCUMULATION OR
OBSTRUCTIONS IN BURNER
5.3
REMOVE CARBON AND CLEAN COMBUSTION
ASSEMBLY
8
DEFECTIVE FLAME TUBE AND
BURNER CHAMBER
5.3.2
5.3.5
REPLACE FLAME TUBE
REPLACE BURNER CHAMBER
9
DEFECTIVE BURNER HOUSING
5.3.7
REPLACE BURNER HOUSING
RESTART HEATER
10
DEFECTIVE FUEL INJECTOR
5.5.5
REPLACE FUEL INJECTOR
RESTART HEATER
11
DEFECTIVE WIRING HARNESS
5.5.6
REPLACE WIRING HARNESS
RESTART HEATER
12
DEFECTIVE ELECTRONIC
PROGRAMMED CONTROLLER
BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED
CONTROLLER
RESTART HEATER


Back to Top