TM 9-2540-207-14&P
6-33
6.5.41 F5 - OVER CURRENT (Design Iteration 1 & 2 Only)
THE HEATER HAS DETECTED THAT THE CURRENT DRAWN FROM THE VEHICLE HAS
EXCEEDED THE NORMAL OPERATING LIMIT OF 20 AMPS
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
WITH HEATER OFF, CHECK FOR
FREE ROTATION OF THE VENT
IMPELLER BY SPINNING BY HAND
5.2.4
5.2.6
IF IMPELLER DOES NOT ROTATE FREELY,
REPLACE VENT FAN IMPELLER AND MOTOR
RESTART HEATER
2
DEFECTIVE POWER AND WIRING
HARNESSES
5.5.6
REPLACE BOTH LOGIC AND WIRING
HARNESSES
RESTART HEATER
3
DEFECTIVE ELECTRONIC
PROGRAMMED CONTROLLER
BOARD
5.2.5
REPLACE ELECTRONIC PROGRAMMED
CONTROLLER
RESTART HEATER
6.5.42 F5 - OVER CURRENT (Design Iteration 3 Only)
THE HEATER HAS DETECTED THAT THE CURRENT DRAWN FROM THE VEHICLE HAS
EXCEEDED THE NORMAL OPERATING LIMIT OF 20 AMPS
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
1
WITH HEATER OFF, CHECK FOR
FREE ROTATION OF THE VENT
IMPELLER BY SPINNING BY HAND
NOTE: IF ON TEST STAND, BE SURE
THAT POWER SUPPLY/ TEST
APPARATUS IS NOT CURRENT
LIMITING
5.2.4
5.2.6
IF IMPELLER DOES NOT ROTATE FREELY,
REPLACE VENT FAN IMPELLER AND MOTOR
RESTART HEATER
2
CHECK IGNITER RESISTANCE
MEASURE THE RESISTANCE OF THE IGNITER
IF LESS TRHAN 1.6 TO 1.8 OHMS
REPLACE IGNITER
RESTART HEATER
3
DEFECTIVE WIRING HARNESSES
REPLACE WIRING HARNESSES
RESTART HEATER
4
DEFECTIVE VENT FAN BOARD
REPLACE VENT FAN BOARD
RESTART HEATER
5
DEFECTIVE POWER BOARD
REPLACE POWER BOARD
RESTART HEATER
6
DEFECTIVE LOGIC BOARD
REPLACE LOGIC BOARD
RESTART HEATER


Back to Top