TM 9-2540-207-14&P
6-27
THE HEATER WAS UNABLE TO ESTABLISH IGNITION IN THE 3½ MINUTE TIME LIMIT
CHECK/POSSIBLE CAUSE
REF
.R
EPAIR
13
CHECK CONDITION OF FLAME
TUBE AND BURNER CHAMBER
5.3.2
5.3.5
REPLACE FLAME TUBE AND BURNER
CHAMBER
RESTART HEATER
14
WICK IS DEGRADED
5.3.6
REPLACE BURNER CARTRIDGE
15
CHECK FOR LOOSE
CONNECTIONS BETWEEN THE
VENT FAN BOARD AND THE
LOGIC BOARD
RECONNECT THE P11 PLUG INTO THE VENT
FAN BOARD AND THE P1 PLUG INTO THE
LOGIC BOARD
RESTART HEATER
16
CHECK WIRE HARNESS FOR
CONTINUITY AND SHORTS
CHECK 2 WIRES FROM THE VENT FAN BOARD
TO THE LOGIC BOARD FOR CONTINUITY AND
SHORT TO GROUND:
P11-PIN12 TO P1-PIN3
P11-PIN4 TO P1-PIN12
CHECK
FOR MV SIGNAL
BETWEEN
P11-PIN13 AND P11-PIN5 FOR BT SENSOR
P11-PIN14 AND P11-PI N 6 FOR XT SENSOR
CHECK FOR OPEN LINE BETWEEN
P11-PIN13 TO CHASIS GROUND AND
P11-PIN14 TO CHASIS GROUND
IF ANY CHECK FAILS
REPLACE WIRE HARNESS
RESTART HEATER