TM-9-2815-220-24

AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL FOR AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

  TM-9-2815-220-24 - Page 1145 of 1563

TM 9-2815-220-24
0137 00
CRANKCASE REPAIR
WP 0137 00-5
INSPECTION (Continued)
CAUTION
Do not tighten studs (
9
) beyond 208 foot-pounds.
Damage to
crankcase or stud may occur.
3. Check main bearing cap stud (9) torque.
a. Studs (9) must be tight at 38 foot-pound minimum torque.
Studs that reach setting height
before reaching 38 foot-pounds torque must be replaced.
b. Mark studs (9) that do not tighten at 38 foot-pounds of torque for replacement.
9 (28 places)
4. Check inside diameter of starter idler gear
shaft bore (A).
Replace crankcase if
measurements are not within limits
(see table below).
5. Measure inside diameter of generator idler
gear shaft bore (B).
Replace crankcase if
measurements are not within limits
(see table below).
REPAIR STANDARDS:
Location
Point of Measurement
Size and Fit of New Parts
min./max. [inches (mm)]
Wear
Limits
A
Inside diameter of starter idler gear
shaft bore in crank case
1.1808
(29.99232)
1.1818
(30.01772)
1.1824
(30.03296)
B
Inside diameter of generator idler gear
shaft bore in crank case
1.1808
(29.99232
1.1818
(30.01772)
1.1824
(30.03296)
B