TM 9-2815-220-24
ENGINE ABNORMAL OIL PRESSURE
0018 00
MALFUNCTION 11:
Generator oil pressure abnormal (650 Ampere generator, PN 11655469 only).
PROBABLE CAUSE
CORRECTIVE ACTION
b. (Continued) Generator oil pump failure.
(2) Replace generator (WP 0051, Generator
Replacement (650 Ampere) (2CA).
c.
Drive clutch failure.
(1) Perform Clutch Test as follows:
PROCEDURE
OBSERVATION
ANALYSIS
If slippage occurs
below 167 foot pounds,
drive gear assembly is
defective.
Torque check (generator removed).
Check slip torque of drive gear
assembly with generator coupling
tool and torque wrench (300 foot-
pound capacity).
Note if there is slippage of
the drive gear while
increasing torque to
167 foot pounds.
If no slippage occurs
below 167 foot pounds,
slip torque is
acceptable, but gear
assembly may have
other damage (low
torque rate).
Proceed to
2 below.
If rotation is more than
8
°
, but less than 17
°
,
drive gear assembly is
satisfactory.
Check torque rotational deflection
rate.
Using tool and torque wrench
as in 1 above, apply 167 foot-pound
torque.
Note deflection in degrees
from zero torque to 167
foot-pound torque.
If rotation is greater
than 17
°
, or less than
8
°
, the drive gear
assembly is defective.
END OF WORK PACKAGE
WP 0018 00-6