TM 9-2815-220-24
FUEL SUPPLY PUMP REPLACEMENT (2CA AND 2DA)
0047 00
WP 0047 00-3 (4 blank)
PURGE FUEL SYSTEM
1.
Turn master switch and in-tank fuel pump switches to "ON" position.
2.
Operate in-tank fuel pump for 1 or 2 minutes.
Simultaneously operate purge pump,
completing 4 or 5 strokes after firm handle pressure is noted.
U
CAUTION
Do not depress flame heater button. Damage to engine could occur.
3.
With in-tank pumps operating, open bleeder valves (12, 13) (on cover of both primary (14) and
fuel/water separator (15) filters) until all fuel (no air) is noted.
4.
Close bleeder valves (12, 13) when fuel flows from both.
END OF WORK PACKAGE
WARNING
12
13
15
14