TM 9-2815-220-24
STARTER/ SMOKE GENERATOR/ DUST
DETECTOR WIRING HARNESS REPLACEMENT,
LVPM CRANKCASE MOUNTED (2CA, 2DA) (PN 11655456, 11682726)
0061 00
INSTALLATION (Continued)
NOTE
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in steps 6 and 7.
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in steps 4 and 5.
7.
Install single-solenoid smoke generator harness lead (33).
a. Install connector (44) at smoke generator solenoid (45).
b. Install screw (46) with new lock washer (47) (item 93, WP 0175) securing ground
lead (48).
c. Install loop clamps (54) with assembled washer screws (53).
d. Install tie wraps (49) (item 81, WP 0175) as necessary.
46, 47
48
49
45
44
33
WP 0061 00-21