TM 9-2815-220-24
DUST EJECTOR SYSTEM REPLACEMENT
0083 00
WP 0083 00-10
13
11
12
INSTALLATION (Continued)
2. Install right bank ejector tube (11).
a. Installation procedure is the same as left
bank except install transmission breather
tube (12) by fastening nut (13).
15, 16
14
15, 16
8
3. Install scavenge tube (8) and exhaust pipe
cap (14).
a. Place scavenge tube (8) and exhaust pipe
cap (14) into position as an assembly.
b. Secure using two screws (15) and new
self-locking nuts (16) (item 38,
WP 0175).
END OF WORK PACKAGE