TM 9-2990-206-34&P
ASSEMBLY-Continued.
INSTALL “()”
RINGS, FILTER RETAINING STRAP, AND
FILTER
IN
DUST DETECTOR COVER
TOOLS :
None
NOTE
This procedure applies to "clean
air” turbosupercharger only
INSTALLATION:
1. Install three new preformed packings
(A) in grooves in underside of dust
detector cover (B).
2. Assemble filter retaining strap (C)
and filter (D), and install in recess
in underside of dust detector cover.
TA293558
Change 1
3-29