PS Magazine - TB 43-PS-556

PS, The Preventative Maintenance Monthly

ISSUE 556

MARCH 1999

PS Magazine - TB 43-PS-556 - Page 25 of 34
AN/VDR-2 Radiac Set . . .
If the window becomes dirty, clean
it carefully with a dry cotton swab.
NBC NCOs, remember the probe and
radiac meter have been calibrated to-
gether. If either malfunctions, don’t try
to fix the problem by swapping com-
ponents with another AN/VDR-2. That
won’t work. Turn in the entire radiac
set to TMDE for repair.
Keep the beta shield closed as much
as possible to protect the delicate probe
window. When you scan, be careful
not to brush the probe against anything.
Even a pin prick in the window can
ruin the probe.
tion that says TURN OFF POWER
BEFORE PLUGGING IN OR UN-
PLUGGING PROBE.
If you don’t pack the AN/VDR-2
right, you damage the probe cord or
the batteries. Packing goes like this:
Put the probe in first with its high
range assembly to the center and its
sensing end up. Pass the cord through
In the field, remember that the radiac
meter will be zapped if you connect or
disconnect the probe with the power
on. A good reminder is to tape a small
sign next to the probe cable connec-
-sob-
i just
failed
that
self-test
!
maybe we
need to
work out
more
!
you
guys just
need a little
pm
.
Cable fraying?
Clamp working?
Put probe
in first.
..
...cord
second.
..
...radiacmeter last
Put sign here
Pin hole can ruin window
f your AN/VDR-2 radiac set is to
be sensitive to radiation threats, it needs
a bit of sensitive PM from you.
Before you go to the field, eyeball
the cable from the probe to the radiac
meter for fraying, especially at the con-
nectors. If the cable’s in bad shape, the
AN/VDR-2 will flunk the self-test.
TMDE needs to check out or replace
the cable.
Make sure the clamp will hold the
beta shield open. If it doesn’t, you’ll
have trouble scanning. TMDE can re-
place the clamp with an improved
clamp that solves the problem.
the opening in the compartment flaps
and store it in the bottom of the case
on the right. Put the radiac meter on
top of the cord.
PS 556
43
MAR 99
PS 556
42
MAR 99


Back to Top
Back to Top