12-96. TROOP/CARGO WINTERIZATION HEATER FILTER-TO-BULKHEAD COUPLING
FUEL SUPPLY HOSE REPLACEMENT (Cont’d)
12-146
Change 4
SMI 9-2320-387-14&P-1
FOLLOW-ON TASKS: • Install heater guard assembly (para. 12-98).
• Operate troop/cargo heater (TM 9-2320-387-10) and check for fuel leaks.
b. Installation
1.
Connect filter-to-bulkhead coupling fuel supply hose (1) to bulkhead coupling connector (5) with
clamp (4).
2.
Connect filter-to-bulkhead coupling fuel supply hose (1) to filter connector (3) with clamp (2).