2500 Gallon Tank Removal
Tag and mark all piping, tubes, and electrical conduit tubing before removal.
Remove nut (1) and hose (2) from tank level sensor (3).
Disconnect three connectors (4, 5, and 6).
Remove two nuts (7 and 8) and tubes (9 and 10) from elbows (11 and 12).
Remove two nuts (13) screws (14) and coupling halves (15) from coupling gasket (16).
Push coupling gasket (16) onto pipe (17).