TB 9-2320-280-35-12
5-30
Figure 5-40.
Section XVI. EPLRS DUAL MOUNT INSTALLATION
16-1.
Insert two screws (14) and lockwashers (13) in holes (12).
16-2.
Using EPLRS rack spacer (9) as template, locate, mark, and drill two 0.3125-in. diameter holes (11)
in top shelf of multi-net rack (10).
16-3.
Enlarge two holes (11) in EPLRS rack spacer (9) to 0.3125-in. diameter.
16-4.
Using EPLRS rack spacer (9) as template, locate, mark, and drill two 0.3125-in. diameter holes (15)
in EPLRS dual mount lower half (8).
16-5.
Enlarge four holes (3) in EPLRS dual mount upper half (2) to 0.3125-in. diameter.
16-6.
Attach EPLRS mount (1), rack spacer plate (9), and EPLRS dual mount lower half (8) to multi-net
rack (10) with four screws (14), washers (16), lockwashers (13), and nuts (17).
16-7.
Attach EPLRS dual mount upper half (2) to EPLRS dual mount lower half (8) with six screws (7),
six lockwashers (5), twelve washers (4), and six nuts (6).
16-8.
Attach EPLRS mount (1) to EPLRS dual mount upper half (2) with four screws (14), washers (16),
lockwashers (13), and nuts (17).
8
9
11
10
14
13
~
~
1
1
6
5
4
17
16
7
4
4
7
2
3
2
~
11
12
9
10
~
~
1. MOUNT, RESILIENT – MT- 6146/VSQ-1 – QTY. 2
2. UPPER BASE – A3265626 – QTY. 1
4. WASHER – MS27183-10 – QTY. 12
5. LOCKWASHER – MS35338-44 – QTY. 6
6. NUT – MS51967-2 – QTY. 6
7. SCREW – MS90725-8 – QTY. 6
8. LOWER BASE – A3265624 – QTY. 1
9. SPACER PLATE – A3265625 – QTY. 1
13. WASHER – MS27183-12 – QTY. 8
14. SCREW – MS90725-36 – QTY. 8
15. LOCKWASHER – MS35338-45 – QTY. 8
16. NUT– MS51967-5 – QTY. 8