5-120
TB 9-2320-280-35-15
Figure 5-135.
40-38.
Route NTDR power cable (64) and lower SINCGARS power cable (65) from battery box (3) through
hole (63) in frame (62).
40-39.
Route EPLRS power cable (58) and upper SINCGARS power cable (59) over frame and behind
multi-net rack (66). Secure cables (58) and (59) with loop clamp (60) and self-tapping screw (61).
40-40.
Route ground cable (74) to shunt (13).
40-41.
Route cable (72) from shunt (13) to rear battery. Secure cables (72) and (74) with screw (73).
40-42.
Route cable (31) from shunt (13) to terminal block. Secure cables (75) and (31) to shunt (13) with
screw (76).
40-43.
Route cable (77) from solenoid (21) to negative terminal.
40-44.
Route cable (71) from solenoid (21) to rear battery. Secure cables (71) and (77) to solenoid (21) with
nut (70).
40-45.
Secure cable (30) to solenoid (21) with washer (67) and nut (68).
40-46.
Route cable (78) from solenoid (21) to negative terminal.
40-47.
Secure cable (78) to solenoid (21) with nut (69).
58. EPLRS POWER CABLE – A3004939 – QTY. 1
59. UPPER SINCGARS POWER CABLE – A3014039-2 – QTY. 1
60. LOOP CLAMP – MS21333-75 – QTY. 1
61. SELF-TAPPING SCREW – 9421073 – QTY. 1
64. POWER CABLE (NTDR) – 8174912-2 – QTY. 1
65. LOWER SINCGARS POWER CABLE – A3014039-2 – QTY. 1
66
58
59
63
64
65
60
61
~
3
~
62