TB-9-2320-302-13-P-3

CREW PROTECTION KIT; AIR CONDITIONING KIT PART 3 OF 3

TECHNICAL BULLETIN; OPERATOR’S, UNIT, AND DIRECT SUPPORT, MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS, AND REPAIR PARTS AND SPECIAL TOOLS LIST

MARCH 2008

  TB-9-2320-302-13-P-3 - Page 7 of 240

TB 9-2320-302-13&P-3
e
Receiver/dryer unit will fall when clamps are loosened. Support receiver/dryer while loosening clamps. Fail-
ure to comply may cause injury to personnel.
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
WARNING
RECEIVER/DRYER
WARNING
REFRIGERANT


Back to Top