2-226
TB 9-2510-251-13
2-2.3
Installation of Air Conditioning Kit to M1097A2 Two-Door with O'Gara Hess
Add-on-Armor (Cont’d).
d. Install Refrigerant Hoses
CAUTION
•
When installing hoses, be sure to secure away from hot or moving parts.
Failure
to comply may result in damage to equipment.
•
Avoid routing hoses in areas where chafing, punctures, or pinching may occur.
Failure to comply may result in damage to equipment.
•
DO NOT remove caps from hoses until ready to charge air conditioner system.
Failure to comply may cause contamination of system and damage to equipment.
•
Keep all fittings capped until just prior to connecting hoses.
Failure to comply
may result in damage to equipment.
•
Keep ends of hoses covered during routing to avoid contamination.
Failure to
comply may result in damage to equipment.
•
Before connecting fittings, check to see that O-rings are present and undamaged.
Failure to comply may result in damage to equipment.
•
Lubricate O-rings with mineral oil just prior to connecting fittings to components
or inserting fittings into hoses.
Failure to comply may result in damage to
equipment.
NOTE
•
Route hoses according to the diagram shown.
Follow existing routing
and tie strap to secure.
DO NOT connect any hoses at this time.
•
Use hydraulic caps or tape closed ends of hoses to prevent debris from
entering system during routing procedure.