d. Install Refrigerant Hoses (Cont’d)
(14)
Connect Condenser.
a.
Four-door vehicles only:
Lubricate O-ring and install #6 female straight fitting on outlet
(smaller) fitting on condenser.
b.
Two-door vehicles only:
Lubricate O-ring and install #6 female 45° fitting (22) on outlet
(smaller) fitting on condenser.
c.
Lubricate O-ring and install #8 female straight fitting (23) to inlet (larger) fitting on
condenser.
d. Trim ends of #6 hose (24) from drier and connect to right fitting.
e. Trim ends of #8 hose (25) from compressor and connect to left fitting.
f.
Reinstall plywood panel on top of transmission tunnel by notching around drain hoses
and refrigerant lines.
(15)
Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and
refrigerant lines.
23
24
22
25
Figure 2-236.
Condenser Connection