4-28
TB 9-2510-251-13
4
4-15
Air Conditioner Unit Repair (Cont’d)
18
20
19
c. Evaporator Coil Replacement
1)
Remove access panel.
2)
Remove evaporator coil (18) from access cover (4).
3)
Install evaporator coil (18) to access cover (4).
4)
Replace access panel.
d. Filter Element Replacement
1)
Release two tension clips (19) and remove filter element (20) from access cover (4).
2)
Remove two gaskets (21) from access cover (4).
3)
Install two gaskets (21) to access cover (4).
4)
Install filter element (20) to access cover (4).
5)
Secure two tension clips (19).
21