Condenser Repair (Cont’d)
d. Condenser Coil Replacement
1)
Remove twelve screws (13) and frame bracket (12) from condenser coil (9).
2)
Install twelve screws (13) and frame bracket (12) to condenser coil (9).
e. Electrical Filter Assembly Replacement
1)
Remove two screws (14) and mounting brackets (15) from frame bracket (12).
2)
Remove four screws (16) and access covers (17) from mounting plate (18).
3)
Remove four clip nuts (19), gasket (20), and electrical filter assembly (21) from mounting
plate (18).
4)
Install electrical filter assembly (21) and gasket (20) to mounting plate (18) with four clip
nuts (19).
5)
Install access covers (17) to mounting plate (18) with four screws (16).
6)
Install mounting brackets (15) to frame bracket (12) and secure with two screws (14).
f.
Follow-On Maintenance
1)
Connect wiring.
2)
Connect refrigerant hoses.
3)
Connect batteries.
4)
Air conditioning system purged and charged (para 4-14).