Air Conditioner Unit Repair (Cont’d)
e. Access Cover Repair (Cont’d)
13)
Install circuit breaker (37) to access cover (4) and secure with nut (36).
14)
Install tension clip (19) and rivet (35) to access cover (4).
15)
Install two O-rings (34) and access cover (32) to expansion valve (31).
16)
Install expansion valve (31) and access cover (32) to access cover (4) and secure with
screw (30) and nut clip (33).
17)
Install angle bracket (29) to access cover (4) and secure with two screws (28).
18)
Install plate (26) and gasket (27) to access cover (4) and secure with six screws (25).
19)
Install grommet (24) to access cover (4).
20)
Install mounting bracket (23) to access cover (4) and secure with four screws (22).
21)
Install filter element.
22)
Install evaporator coil.
23)
Install distribution plenum and centrifugal fan.
24)
Install access panel.
f.
Follow-On Maintenance
1)
Connect wiring.
2)
Connect refrigerant hoses.
3)
Connect batteries.
4)
Air conditioning system purged and charged (para 4-14).
/(4-31 Blank)


Back to Top