TB 9-3950-253-13&P
Change 1
0029-10
0029
REMOVAL – CONTINUED
Stowage Guide Sensor Harness Removal
00029
NOTE
Perform steps 1 through 3 for both right and left sides.
1. Disconnect stowage guide sensor harness (Figure 9, Item 3) from stowage guide sensor (Figure 9, Item 2).
2. Remove four bolts (Figure 9, Item 5), two cable clamp caps (Figure 9, Item 6), and stowage guide sensor
harness (Figure 9, Item 3) from stowage guide (Figure 9, Item 4).
3. Disconnect stowage angle sensor harness (Figure 9, Item 7) from stowage angle sensor (Figure 9, Item 1).
Figure 9.
Stowage Sensor Harness Removal.
0029
5
4
3
2
1
7
6
3