2-12.
OPERATING PROCEDURES -cont.
Nozzle Disconnection.
Refer to figure 2-13.
CAUTION
If control lever is not in the full CLOSED position (against mechanical stop),
internal fuel pressure will force the poppet into the OPEN position.
(6)
Rotate control lever (5) to the full CLOSE position (against internal mechanical stops).
(7)
Grasp handles (3) and rotate nozzle body (2) to the left until nozzle body disconnects from aircraft adapter
(4).
(8)
Install dust cover (1) on end of nozzle body (2).
NOTE: Model HTARS100 nozzle shown.
Model HTARS101 nozzle is similar.
Figure 2-13.
Single Point Refueling Nozzle (D1) Operation.
2-34
Change 4


Back to Top